• AC
Variable Speed Drives / Inverters
The Automation Direct VSD’s come in three
different models that range from compact inverters
to 75kW sensorless vector drives. Key
features as follows; GS1 Series
Mini Drives • Affordable
and compact inverters • 0.2 – 1.5kW,
Single / Three Phase Applications • Offers
V/HZ control with advanced application features
• Configured using keypad or built-n RS485
serial port • 1 x Analog Input, 4 x Digital
Inputs, 1 x NO Relay Output GS2
Series Micro Drives
• All features of GS1 Drive plus Dynamic Braking,
PID, Removable
Keypad (used for advanced diagnostics)
• 0.2 – 7.5kW, Single / Three Phase
Applications • Configured using keypad
or built-in RS485 serial port • 1 x Analog
Input, 6 x Digital Inputs, 1 x Analog Output, 2
x Relay Output DURApulse AC Drives
(GS3 Drives) • Sensorless
Vector Drives built on simplicity of GS1 / GS2 Drives
• Available in 1 – 100 Hp models
• Sensorless Vector, Closed Loop Control &
Auto-tuning • 175% Starting Torque and
150% rated current for one minute • Variable
carrier frequency (depending on model) •
Automatic Torque and Slip Compensation •
Programmable Jog Speed • Optional encoder
feedback for enhanced speed control •
Configured using keypad, RS485 and Ethernet (optional)
• 3 x Analog Inputs, 11 x Digital Inputs,
1 x Analog Output,
1 x SPDT Relay Output •
Optional software package • Two year replacement
warranty (subject to conditions) |
|
| |
|
• Stepper
& Servo Motors
Automation Direct features both the SureStep®
stepper motors which provide a low-cost reliable,
high quality solution for positioning control needs
as well as the SureServo® range of brushless
fully digital servo systems. A list
of key features of these systems are given below;
SureStep® Stepper Motors
• Four Standard Motors and a “one-size-fits-all”
stepper motor drive • Holding torques
from 83 oz-inch to 434 oz-inch • NEMA
size 17, 23 or 34 frames • Operate on
2.8A per phase (size 17 motor uses 2.0A) •
Comes with 20-foot extension cable • Interfaces
to 2-phase micro-stepping drive • Features
+5VDC optically isolated logic inputs SureServo®
Servo Systems • Complete
systems (includes Drive, Motor & Accessories)
• Eight standard systems from 100 W to 3 kW
• Use with DirectLOGIC PLCs or any other host
control • Drives feature on-board indexer
and adaptive tuning modes • Free set-up
software • 30-day money-back guarantee
• 2 year warranty |
|
| |
|
• Powerline IEC Contactors
Our PowerLINE motor controls (by AutomationDirect)
line of load switching devices gives you high quality
contactors with the same features as the big brands,
but at prices that are hard to believe!
Some key features; • Common
side & front mounted auxiliary contact blocks
up to 70A. • Diagonal or top, wiring
options for coils up to 70A contactor. •
Front access to contacts • Shrouded terminals
for safety against accidental touch •
DIN rail mounting up to 140 A Contactors •
Wide range of accessories which includes add on
Auxillary Contact Block - front & side
mounted, Electronic Star Delta Timer, Surge Suppressors,
Wide band Coils, Mechanical Interlock.
Click here to Download Brochure • IEC:947-4,
IS:13947-4 • Prices start at $15
for a 4kW contactor! |
|
| |
|
• Thermal Overload
Relays
A wide range of bi-metal thermal overload relays
are offered for close protection of motors &
other inductive loads against overload, single phasing
&
unbalanced system voltages. Some key
features; • Auto / Manual reset
• Contactor Mounting – 0.16A to 80A
in 26 direct reading version • Individual
Mounting – 0.16A to 34A in 18 direct reading
version • CT Operated – 24A to 400A
in 8 current transformer operated version •
Conforms to IEC:60947-1&4 / IS:13947-1&4
• Protection against overload & single
phasing • Manual or auto reset facility
• Ambient temperature compensated •
Off & test mode facility in certain sizes
• Individual or DIN Rail mounting facility
• Matching to the contactor size up to 80A |
|
| |
|
• Manual Starters
/ Protectors
GH Series motor starter/protectors (MSP) offer all-in-one
motor protection for many applications. Contained
in one unit is motor overload protection, instantaneous
short circuit trip, phase loss protection and ON/
OFF switching with lockout/ tag-out capability.
Add an optional shunt trip for remote tripping of
the MSP, or an optional under-voltage release for
tripping the MSP when an under-voltage situation
occurs.
Auxiliary contact blocks are also available for
signaling pilot lights, PLC inputs, control circuits,
etc. Add a GH Series contactor for a complete remote
motor control solution. Some key features;
• Push on / push off manual control disconnects
power from motor • Electromagnetic short
circuit protection eliminates the need for separate
breakers or fuses. • Overload heater strips
protect the motor from sustained overload conditions.
• Phase loss detection trips when a phase
is lost to protect the motor • Options
include under-voltage trip, remote shunt trip, and
aux. contacts |
|
| |
|
• Miniature Circuit
Breakers
MCB’s have precision formed moulded case &
cover of flame retardant high strength thermo plastic
material having high melting point, low water absorption,
high dielectric strength and temperature with stand.
Some key features; •
6A – 63A in 'B' Curve, 0.5A – 63A in
'C' Curve, 0.5A – 63A in 'D' Curve, 0.5A –
63A for DC Applications •
Single Pole, Single Pole & Neutral, Double Pole,
Three Pole, Three Pole & Neutral, Four Pole
• Uniform 10KA breaking capacity for 'B' and
'C' Curve • Low power consumption, thus
cost effective & energy saving •
Suitable for DC and for a wide frequency range of
50Hz - 400Hz application •"Finger
Safe" terminals - IP 20 degree of protection
• Dual Termination facility. •
15 Plate Arc Chute for effective arc quenching.
• Silver Graphite contacts for enhanced
life • Accessories (Auxiliary Switch,
Shunt Trip) • IEC:60898-1995/IS-8828-1996 |
|
| |
|
• Residual Current
Circuit Breakers
The flow of current through electrical facilities
always involves risks. Poorly insulated equipment,
faulty wires and incorrect use of an electrical
devise cause currents to flow through the wrong
path (i.e., through the insulation) to the earth.
This current is called ‘Leakage Current’.
Some key features; •
16A – 63A Range • 30mA, 100mA, 300mA,
500mA Sensitivity • Double Pole, Four
Pole Execution • Simple and Robust operating
mechanism • Rotary handle with ON/Off
indication • Dual termination for Bus
Bar as well as cable connection • Advance
Neutral • Test Button for regular inspection
• IEC 61008 - 1 / IS 12640 - 1: 2000 |
|
| |
|
• Residual Current
Circuit Breakers with Overcurrent Protection
The latest & most innovative addition to Havell's
product range; RCBO provides human safety that is
protection against electrical shock, short circuit,
fire hazards & indirect contacts. It also provides
Protection to all types of electrical gadget/installation
from overload hazards. Some key features;
• 16A, 20A, 25A, 32A, 40A, 50A Range
• Double Pole Execution • IS 12640
(Part 2) : 2001 & IEC 61009-2-1 |
|
| |
|
• Fuji Motor Controls
AutomationDirect has partnered with Fuji Electric
to offer a complete line of IEC controls.
The following options are available;
Manual Motor Starters (BM3 Series)
• Provide Circuit Breaker functions and
Overload Relay functions • Meet cUL listed
Group Installation Regulations of National Electrical
Code (NEC) • Reduce the number of Circuit
Breakers or Fuses in your motor control panel
• 32A frame size (45mm width) and 63A frame
size (55mm width) standard and high
breaking capacity models available Contactors
and Overload Relays (SC-M / SC-E / TK-E Series)
• Offer new SC-M series Mini Contactors
(up to 5HP at 480VAC), SC-E series Contactors
and TK-E series Overload Relays (up to 100HP
at 480VAC) • Both SC-M and SC-E series
Contactors have 24VAC,120VAC, 240VAC, 24VDC and
various other operating coil voltages
Combination Starters
• Fuji MMS can be combined with an SC-M
series Mini Contactor and SC-E series Contactor
for a combination starter •
Fuji MMS Type E and F, cUL listed as Self-Protected
Combination Controllers, replace a UL489
Circuit Breaker or Fuse in a motor branch circuit
Odyssey Series Contactor – Fuji’s
unique “Super Magnet” technology
• “Super Magnet” operation
is electrically controlled. NO chattering, NO contact
welding and NO coil burning! •
“Super Magnet” accepts AC or DC coil
control voltage in 24V, 48V, 120V and 240V •
Odyssey series available up to 300HP at 480VAC;
Orange line series available up to 10HP
at 480VAC MMS Combination Starter
• By utilizing the UL Type E rating of
the Fuji manual motor starter, a combination starter
can be constructed and wired in less
time and at a lower cost while minimizing enclosure
space requirements • The
MMS is classified as a self-protected motor control
device, allowing for group motor control
without the need for separate motor branch circuit
protection. The MMS provides short circuit,
motor overload, and phase loss protection as well
as ON / OFF control with lockout capability.
When combined with a Fuji SC-E series contactor,
remote motor control is possible with
a minimum amount of space requirements |
|
| |
|
• Push Buttons &
Indicators
The AutomationDirect 22mm Metal Push Buttons, Selector
Switches and Non-metal Indicator Light products
are typically about 50% of the list price of competitors.
This rugged yet economical line of metal pilot devices
should provide solutions for all your operator panel
designs. Nothing has been sacrificed to offer you
the highest quality rotary switch, emergency stop
switch and momentary push button switch products
at the lowest prices. Choose from a complete line
of illuminated or non-illuminated momentary push
button switch products and emergency stop switch
and rotary switch products. A variety of accessories
are also available. Some key features;
• Chrome-plated alloy operator is attractive
and corrosion resistant; operators
protected to IP65
• Support base mounts into panels up to 6
mm thick. Secure mounting method
eliminates twisting in mounting hole •
Self-cleaning gold-plated silver contacts provide
reliable low energy switching
• Mount up to six contact blocks in any combination
to a support base (two wide by
three deep) •
Pressure plate wire terminals for easy, secure wiring,
accept up to 14 AWG wire • Contacts rated
at 10 amps thermal current
• Six colors available in pushbuttons, illuminated
pushbuttons and indicating lights,
including red,
green, yellow, blue and white (clear for indicating
devices) |
|
| |
|
• Relays & Timers
Industrial Control Relays
General purpose industrial control relays are available
in cube, card, and solid state relay styles for
use in a wide range of applications. All relays,
including the solid state relay, feature LED indicators
for easy troubleshooting. Models available
include; • Cube relays (available
in 24 VDC, 120 VAC and 240 VAC coil voltages, plug
into DIN-rail mountable relay sockets)
• The RS series utilizes slim plug-in
24 VDC card relays to create a bank of four or
six units in DIN-rail mountable terminal
modules • 12 Amp electro-mechanical relays
are available in 24 VDC, 24 VAC, 120 VAC, and
240 VAC coil voltages • Solid state
relays (10 or 25 amp loads), also available in shock
and vibration resistant assembly
Timer Switches & Relays
AutomationDirect offers solid-state timers brought
to you by two leaders in the industry, FUJI Electric
and Koyo. All timer relays meet UL and CE conformity.
Whether you need a miniature DIN timer, a 1/16 DIN
timer, or a full-blown 1/16 DIN digital timer switch,
and whether you need to time in seconds or hours
we can supply a timer relay that fits your needs.
Models available include;
• 1/16 DIN Digital Timers by Koyo feature
large and easy to read displays with
12mm character display • 1/16 DIN Super
Timers are plug in 8-pin or 11-pin surface/ DIN
rail mountable with up to four selectable
modes of operation and four selectable timing ranges
• Fuji Miniature DIN Timer Relays are compact
and highly accurate and offer an on-delay
operation type with a single timing range (Timing
repeat accuracy
within ±1% at maximum setting time) |
|
| |
|
• Isolator Switches
AutomationDirect has introduced a line of non-fused
switch disconnects for breaking and disconnecting
on equipment loads. The SD1 series non-fused disconnects
allow breaking and disconnecting on equipment loads
of up to 600 VAC, at a nominal current range from
16 A to 40 A. SD2 series non-fused disconnects allow
breaking and disconnecting on equipment loads of
up to 600 VAC, at a nominal current range from 63
A to 125 A. Both models are DIN-rail or panel-mountable
and feature high breaking capacity (AC 22 A to AC
23 A), double break contacts, high electrical and
mechanical endurance, and are resistant to damp
heat.
The non-fused disconnects have an IP20 degree of
protection and are HACR rated. Prices for the non-fused
disconnects start at $36.00 . A complete line of
standard accessories is also available, including
an optional auxiliary contact (one normally open
and one normally closed contact) and a door extension
shaft and handle |
|
| |
|
|